Material properties

Max. permitted static load (p)
N/mm²
320
Max. permitted dynamic load (p)
N/mm²
150
Max. sliding speed (U)
m/s
1,0
Max. pU-value at p = 100 N/mm²
N/mm² x m/s
0,5
Max. pU-value at U = 1 m/s
N/mm² x m/s
2
Friction coefficient (dep. on operating cond.) µ
0,05 to 0,15
Temperature range
°C
-190 to +150

Tolerances

Housing bore
H7
Bush (outer-Ø)
t6/u6
Bush (inner-Ø)
H8/H9 after installation
Shaft-Ø
d7/e7/f7/
Shaft hardness
hardness > 180 HB
Shaft surface finish
Ra 0,2 - 0,8 µm
Installation
Press-fit installation
Tolerances
Other installation tolerances are possible provided that a safe fit in the housing and the necessary running clearance are maintained