Material properties
| Max. permitted static load (p) |
N/mm² |
150 |
| Max. permitted dynamic load (p) |
N/mm² |
90 |
| Max. sliding speed (U) |
m/s |
0,4 |
| Max. pU-value at p = 40 N/mm² |
N/mm² x m/s |
0,4 |
| Max. pU-value at U = 0,4 m/s |
N/mm² x m/s |
1,2 |
| Friction coefficient (dep. on operating cond.) |
µ |
0,07 to 0,15 |
| Temperature range | °C |
-100 to +280 |
Tolerances
| Housing bore |
H7 |
| Bush (outer-Ø) |
s6 |
| Bush (inner-Ø) |
E8 for H10 after installation |
| Shaft-Ø |
d8 |
| Shaft hardness |
hardness > 180 HB |
| Shaft surface finish |
Ra 0,2 - 0,8 µm |
| Installation Press-fit or super-cooled installation. |
Tolerances Other installation tolerances are possible provided that a safe fit in the housing and the necessary running clearance are maintained. |
|
GTC • Contact • Imprint • Trademarks |